Paieška

Ieškota: krepselis

Rastos prekės 531

PoE šakotuvas 1000Mbps 16portų +2G uplink

€ 100.83  
16 prievadų 1000M PoE šakotuvas su 2 uplink prievadais 1000M. Ypatybės: PoE šakotuvas turi 16 PoE prievadų po 10/100/1000Mbps ir 2 RJ45 uplink prievadus po 10/100/1000Mbps; 1-16 prievadai palaiko IEEE802.3af/at standartą. PoE šakotuvų standartinė galia yra 15.4W/prievadui, maksimali galia: 30W/prievadui, bendra galia 250W. Su DIP jungikliu (Standard / VLAN). Virtualaus tinklo režimas (VLAN) palaiko kiekvieno PoE prievado izoliaciją. Integruota tinklo prievadų apsauga nuo viršįtampių iki 6 kV. Maitinimo šaltinis integruotas (52V/4.8A), pridedamas maitinimo kabelis. Techniniai duomenys: Prievadai: 16x 10/100/1000Mbps PoE prievadų; 2x 10/100/1000Mbps uplink RJ45 prievadai. Tinklo protokolai: IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3af/at. Įėjimo įtampa: 110-240V AC, 50/60Hz. Maitinimas: pagal nutylėjimą: 1/2(+), 3/6(-). PoE standartai: IEEE802.3af/at. MAC adresų lentelė: 2K. Perdavimo sparta: 100Mbps: 148800pps; 1000Mbps: 1488000pps. Naudojamas kabelis: UTP Cat5e ar naujesnis. Maksimali galia: 30W/prievadui; IEEE802.3af/at. Vidutinė galia: 15.4W/prievadui. Vidinis (Switching) pajėgumas: 12Gbps. PoE maitinimo atstumas: 100m. Bendra galia: 250W (52V, 4.8A). LED indikatoriai: maitinimas; tinklas. Integruotas maitinimo blokas: AC110-240V, 120W. Darbinė temperatūra: -10°C ~ +55°C. Darbinė drėgmė: 10-90% RH. Išmatavimai: 270x181x44 mm. Svoris: 2kg. Montavimas: stelažinis. Garantija: 24 mėnesiai.
Pirkti
Susisiekti dėl likučio

PoE šakotuvas 1000Mbps 16portu+2G uplink + 2SFP

€ 302.50  
PoE šakotuvas 16-Portų, +uplink 2-Port RJ45 + 2-Port SFP, 135W Product Overview DH-PFS3218-16ET-135 is a 100 Mbps dual-port uplink unmanaged PoE switch. It supports functional DIP switch which provides port isolation, long distance power supply, PoE watchdog and QoS control. Featured with Gigabit uplink optical ports, it meets the need of long distance transmission. Applicable to small and micro-scale monitoring networks such as office desktops, schools, hotels, supermarkets, hospitals. Features: • Supports long distance PoE transmission. • Intelligent PoE. • Two-layer industrial PoE switch. • Innovative PoE Watchdog PD Alive. • Smooth Transmission. • MAC auto study and aging, MAC address list capacity is 8K. • Conform IEEE802.3, IEEE802.3u, IEEE802.3x, IEEE802.3ab, IEEE802.3z standards. • Supports PoE IEEE802.3af, IEEE802.3at, Hi-PoE standard. • Port isolation. • Industrial wide temperature design. Technical Specifications: • Model PFS3218-16ET-135. Ethernet Ports: • 1610/100Mbps RJ45 (PoE). • 210/100/1000Mbps RJ45 (uplink). • 2*1000Mbps SFP (uplink) (combo). • PoE Power Consumption Port 1-2=60W, Port 3-16=30W, Total=135W. • PoE Protocol IEEE802.3af, IEEE802.3at, Hi-PoE. • PoE/Hi-PoE PIN Assignment: 1, 2, 4, 5 (V+), 3, 6, 7, 8 (V-). • Switching Capacity 7.2Gbps. • Packet Forwarding 5.3568 Mpps. • Packet Buffer Memory 4Mbit. • MAC Table Size 8K. • Application Humidity 10%~90%RH. • Power AC 100-240V. • Thunder Protection Common Mode 4KV. • Differential Mode 2KV. • ESD Protection Air discharge: 8 kV. • Contact discharge: 6 kV. • Working Temperature: -10°C~55°C. • Dimension(W×D×H) 440mm×300mm×44mm.
Pirkti
Susisiekti dėl likučio

PoE šakotuvas 1000Mbps 8portų +2G uplink +2G SFP

€ 59.31  
8 prievadų 1000M PoE šakotuvas su 2 uplink prievadais 1000M ir su 2 SFP prievadais 1000M. Ypatybės: PoE šakotuvas turi 8 PoE prievadus po 10/100/1000Mbps, 2 RJ45 uplink prievadus po 10/100/1000Mbps ir 2 SFP prievadus po 100/1000Mbps; 1-8 prievadai palaiko IEEE802.3af/at standartą. PoE šakotuvų standartinė galia yra 15.4W/prievadui, maksimali galia: 30W/prievadui, bendra galia 120W. Su DIP jungikliu (Standard / VLAN). Virtualaus tinklo režimas (VLAN) palaiko kiekvieno PoE prievado izoliaciją. AI Watchdog režimas palaiko AI-PoE tinklo savitaisos funkciją, automatiškai sprendžia įrenginių veikimo problemas. 1-2 prievadų prioritetinis duomenų paskirstymas (QoS). Integruota tinklo prievadų apsauga nuo viršįtampių iki 6 kV. Maitinimo šaltinis integruotas (52V/2.3A), pridedamas maitinimo kabelis. Techniniai duomenys: Prievadai: 8x 10/100/1000Mbps PoE prievadai; 2x 10/100/1000Mbps uplink RJ45 prievadai; 2x 100/1000Mbps SFP prievadai. Tinklo protokolai: IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3af/at. Įėjimo įtampa: 110-240V AC. Maitinimas: pagal nutylėjimą: 1/2(+), 3/6(-). PoE standartai: IEEE802.3af/at. MAC adresų lentelė: 2K. Perdavimo sparta: 100Mbps režimu: 148800 pps; 1000Mbps: 1488000 pps. Naudojamas kabelis: UTP Cat5e ar naujesnis. Maksimali galia: 30W/prievadui; IEEE802.3af/at. Vidutinė galia: 15.4W/prievadui. Vidinis (Switching) pajėgumas: 12Gbps. PoE maitinimo atstumas: 100m. Bendra galia: 120W (52V, 2.3A). LED indikatoriai: maitinimas; tinklas. Integruotas maitinimo blokas: AC110-240V, 120W. Darbinė temperatūra: -10°C ~ +55°C. Darbinė drėgmė: 10-90% RH. Išmatavimai: 270x180x44 mm. Svoris: 1.5kg. Montavimas: stelažinis. Garantija: 24 mėnesiai.
Pirkti
Turime sandėlyje

N-male užspaudžiama jungtis RG6 kabeliui

€ 2.97  
N-male užspaudžiama jungtis RG6 kabeliui Techninis aprašymas: Jungties tipas: N-male. Kabelio tipas: RG6.
Pirkti
Turime sandėlyje

RP-SMA-male užspaudžiama jungtis LMR-400 kabeliui

€ 1.90  
RP-SMA-male užspaudžiama jungtis LMR-400 kabeliui Techninis aprašymas: Jungties tipas: RP-SMA-male. Kabelio tipas: LMR-400. Varža: 50 omų.
Pirkti
Susisiekti dėl likučio

RP-SMA-female užspaudžiama jungtis LMR-400 kabeliui

€ 1.90  
RP-SMA-female užspaudžiama jungtis LMR-400 kabeliui Techninis aprašymas: Jungties tipas: RP-SMA-female. Kabelio tipas: LMR-400. Varža: 50 omų.
Pirkti
Turime sandėlyje

PoE šakotuvas 1000Mbps 16portų PoE +2G uplink + 2SFP, Hi-PoE

€ 593.14  
PoE šakotuvas 16x 1000Mbps PoE portų, 2x SFP 1000Mbps, Total-190W Features: • 20-port managed gigabit switch with 16-port PoE. • Transmits data at a high speed through USB 3.0. • Layer 2 network management PoE switch. • Supports web, and network management software based on SNMP. • Network redundancy: STP/RSTP. • Supports PD alive mode. • The red ports support t IEEE802.3af, IEEE802.3at, IEEE802.3bt and the Hi-PoE standards, max 90W. • Intelligent PoE controls over power consumption and offers real-time monitoring. • Non-blocking video transmission due to large buffer memory. • Supports desktop-mount installation. • Supports IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ad standards. • Conforms to IEEE802.3af and IEEE802.3at power supply standard. Technical Specifications: • Model S4220-16GT-190. • Ethernet Port: 18x 10/100/1000Mbps, SFP 2x 1000Mbps; PoE ports: 16x 10/100/1000Mbps. • Ports 1-16: RJ45 10/100/1000 Mbps(PoE); Ports 17-18: RJ45 10/100/1000 Mbps; Ports 19-20: SFP 1000 Mbps. • PoE Power consumption: Full load = 190W, Idling: <20W; Port 1-2 = 90 W, Port 3-16 = 30 W. • Power consumption management: yes. • PoE PIN Assignment: 1, 2, 4, 5 (V+), 3, 6, 7, 8 (V-). • Communication standards: IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ad. • PoE protocol: IEEE802.3af (PoE); IEEE802.3at (PoE+); Hi-PoE; IEEE802.3bt (PoE++). • Switching capacity: 56 Gbps. • Packet forwarding rate: 29.76 Mpps. • Packet buffer memory: 4.1 Mbit. • MAC Table size: 8K. • Jumbo Frame: 10K Byte. • VLAN Number: 4K. • VLAN Interface: 10. • Dynamic ARP: 512. • MTBF: 467125.73 hours. • Long distance PoE: 250 m long distance PoE transmission. • Spanning Tree Protocol: STP; RSTP. • Link Aggregation: Static link aggregation; LACP. • Multicast: IGMP Snooping. • DHCP Function: DHCP client; DHCP-Server; DHCP-Snooping. • Security: IEEE 802.1x ACL. • Equipment Management: WEB(http and https); Telnet; SNMP V1/V2C/V3. • Application humidity: 5%~95%. • Power supply: 48V - 57V DC. • Lightning Protection Common Mode: 4 kV. • Differential mode: 2 kV. • ESD Protection Air discharge: 8 kV. • Contact discharge: 6 kV. • Working temperature: -10°C~55°C. • Weight: 3.405 kg. • Dimensions(W×D×H): 440 mm × 300 mm × 44 mm. Transmission Performance: Switch power supply voltage 53V. CAT5E/CAT6. Max. DC resistance < 10ohm/100m Cable(m) - Load Capacity(W) - Bandwidth(Mbps) IEEE802.3bt 90W: 100m Cable; 71.3W Load Capacity; 1000Mbps Bandwidth. 150m Cable; 62W Load Capacity; 10Mbps Bandwidth. 200m Cable; 51W Load Capacity; 10Mbps Bandwidth. 250m Cable; 40W Load Capacity; 10Mbps Bandwidth. Hi-PoE 60W: 100m Cable; 53W Load Capacity; 1000Mbps Bandwidth. 150m Cable; 50W Load Capacity; 10Mbps Bandwidth. 200m Cable; 47W Load Capacity; 10Mbps Bandwidth. 250m Cable; 37W Load Capacity; 10Mbps Bandwidth. IEEE802.3at 30W: 100m Cable; 25.5W Load Capacity; 1000Mbps Bandwidth. 150m Cable; 25.5WLoad Capacity; 10Mbps Bandwidth. 200m Cable; 25.5WLoad Capacity; 10Mbps Bandwidth. 250m Cable; 25.5WLoad Capacity; 10Mbps Bandwidth. Note: The actual transmission distance may vary due to power consumption of connected devices or the cable type and status.
Pirkti
Turime sandėlyje

N-female užspaudžiama jungtis RG6 kabeliui

€ 2.97  
N-female užspaudžiama jungtis RG6 kabeliui Techninis aprašymas: Jungties tipas: N-female. Kabelio tipas: RG6.
Pirkti
Turime sandėlyje

PoE šakotuvas valdomas100Mbps 8portų+2G uplink, Hi-PoE

€ 168.45  
10 portų valdomas šakotuvas su 8 portų PoE, 250m, 96W. Overview: Cloud Managed Switch is a layer-2 commercial switch that has a long-distance PoE function. It can supply power to devices up to 250 meters away. The PoE red port supplies up to 90W. The Switch can be managed through the DoLynk Care app, allowing you access to the network topology diagram function, which can be used to quickly identify issues. The DoLynk Care app is developed based on DoLynk Care Cloud Server. The Switch is applicable for use in a wide variety of scenarios, such as in homes, factories and offices. Model: S4100-8ET2GT-96-C. Functions: Supports LLDP protocol and automatically generating the network topology to quickly identify issues. Cloud Management: You can operate and maintain the switch on the app of the mobile terminal, greatly reducing the cost of operation and maintenance. The transmission distance of a PoE port can be up to 250 m, meeting the requirement of wired transmission (bandwidth reduced to 10Mbps). · Supports visualized management and remote maintenance. · Supports automatic network topology generation. · 250 m long-distance power supply. · 8-pin PoE offers better compatibility and reduces cable loss. · PoE watchdog monitors the status of terminals in real-time. · Supports the power management policy. Red Port 90W: The red ports support IEEE802.3af, IEEE802.3at, IEEE802.3bt and Hi-PoE standards, with a maximum output power consumption of 90W per port. Suitable for powering high-power devices. PoE Watchdog: It enables the switch to automatically detect port status and restart the failed ports to recover connection in case of IPC connection exception. This enables intelligent operation and maintenance management in its true sense and effectively reduces manual maintenance costs. Technical Specification: Included Power Adapter: Yes. PoE: Yes. Ethernet Port: 8. Ethernet Port Speed 10/100 Mbps. Optical Port Uplink Speed: 10/100/1000 Mbps. Description of Function Slots: Port 1–8: 8 × RJ–45 10/100 Mbps; Uplink1–2: 2 × RJ–45 10/100/1000 Mbps. Power Supply: 53 VDC, 1.81 A. Operating Temperature: –10°C to +55°C. Operating Humidity: 5%–95% (RH), non-condensing. Storage Temperature –40°C to +70°C. Storage Humidity 5%–95% (RH), non-condensing. Power Consumption Idling: <5 W, Full: 96 W. Smart Managed Switch: yes. MTBF: 864,663 h. Switching Capacity: 7.2 Gbps. Packet Forwarding Rate: 4.17 Mpps. Packet Buffer Size: 4 Mbit. MAC Table Size: 16K. PoE Protocol: IEEE802.3af; IEEE802.3at; Hi-PoE; IEEE802.3bt. Communication Standard: IEEE 802.3; IEEE 802.3u; IEEE 802.3X; IEEE 802.3ab. PoE Power: Port 1 <90 W; Port 2–8 <30 W; Total <96 W. PoE Power Consumption Management: Yes. PoE Pin Assignment: 1, 2, 4, 5 (V+), 3, 6, 7, 8(V–). Long Distance PoE Transmission: Yes. Statics Protection: Air discharge: 8 kV; Contact discharge: 6 kV. Lighting Protection: Common mode: 4 kV; Differential mode: 2 kV. Weight: 0.5 kg. Product Dimensions: 190 mm × 100 mm × 30 mm. Certifications CE; FCC. Transmission Performance: Switch power supply voltage 53V. CAT5E/CAT6. Max. DC resistance < 10ohm/100m Cable(m) Load Capacity(W) Bandwidth(Mbps) IEEE802.3bt 90W: 100m Cable; 71.3W Load Capacity; 100Mbps Bandwidth. 150m Cable; 62W Load Capacity; 10Mbps Bandwidth. 200m Cable; 51W Load Capacity; 10Mbps Bandwidth. 250m Cable; 40W Load Capacity; 10Mbps Bandwidth. Hi-PoE 60W: 100m Cable; 53W Load Capacity; 100Mbps Bandwidth. 150m Cable; 50W Load Capacity; 10Mbps Bandwidth. 200m Cable; 47W Load Capacity; 10Mbps Bandwidth. 250m Cable; 37W Load Capacity; 10Mbps Bandwidth. IEEE802.3at 30W: 100m Cable; 25.5W Load Capacity; 100Mbps Bandwidth. 150m Cable; 25.5WLoad Capacity; 10Mbps Bandwidth. 200m Cable; 25.5WLoad Capacity; 10Mbps Bandwidth. 250m Cable; 25.5WLoad Capacity; 10Mbps Bandwidth. Note: The actual transmission distance may vary due to power consumption of connected devices or the cable type and status.
Pirkti
Turime sandėlyje

PoE šakotuvas valdomas100Mbps 4portų+2G uplink, Hi-PoE

€ 115.07  
6 portų valdomas šakotuvas su 4 portų PoE, 250m, 60W. Overview: Cloud Managed Switch is a layer-2 commercial switch that has a long-distance PoE function. It can supply power to devices up to 250 meters away. The PoE red port supplies up to 60W. The Switch can be managed through the DoLynk Care app, allowing you access to the network topology diagram function, which can be used to quickly identify issues. The DoLynk Care app is developed based on DoLynk Care Cloud Server. The Switch is applicable for use in a wide variety of scenarios, such as in homes, factories and offices. Model: S4100-4GT2GT-60-C. Functions: Supports LLDP protocol and automatically generating the network topology to quickly identify issues. Cloud Management: You can operate and maintain the switch on the app of the mobile terminal, greatly reducing the cost of operation and maintenance. The transmission distance of a PoE port can be up to 250 m, meeting the requirement of wired transmission (bandwidth reduced to 10Mbps). · Supports visualized management and remote maintenance. · Supports automatic network topology generation. · 250 m long-distance power supply. · 8-pin PoE offers better compatibility and reduces cable loss. · PoE watchdog monitors the status of terminals in real-time. · Supports the power management policy. Red Port 60W: The red ports support IEEE802.3af, IEEE802.3at, IEEE802.3bt and Hi-PoE standards, with a maximum output power consumption of 60W per port. Suitable for powering high-power devices. PoE Watchdog: It enables the switch to automatically detect port status and restart the failed ports to recover connection in case of IPC connection exception. This enables intelligent operation and maintenance management in its true sense and effectively reduces manual maintenance costs. Technical Specification: Included Power Adapter: Yes. PoE: Yes. Ethernet Port: 4. Ethernet Port Speed 10/100/1000 Mbps. Optical Port Uplink Speed: 10/100/1000 Mbps. Description of Function Slots: Port 1–4: 4 × RJ–45 10/100/1000 Mbps; Uplink1–2: 2 × RJ–45 10/100/1000 Mbps. Power Supply: 53 VDC, 1.226 A. Operating Temperature: –10°C to +55°C. Operating Humidity: 5%–95% (RH), non-condensing. Storage Temperature –40°C to +70°C. Storage Humidity 5%–95% (RH), non-condensing. Power Consumption Idling: <5 W, Full: 60 W. Smart Managed Switch: yes. MTBF: 93.24 years. Switching Capacity: 12 Gbps. Packet Forwarding Rate: 8.93 Mpps. Packet Buffer Size: 1 Mbit. MAC Table Size: 2K. PoE Protocol: IEEE802.3af; IEEE802.3at; Hi-PoE. Communication Standard: IEEE 802.3; IEEE 802.3u; IEEE 802.3X; IEEE 802.3ab. PoE Power: Port 1 <60 W; Port 2–8 <30 W; Total <60 W. PoE Power Consumption Management: Yes. PoE Pin Assignment: 1, 2, 4, 5 (V+), 3, 6, 7, 8(V–). Long Distance PoE Transmission: Yes. Statics Protection: Air discharge: 8 kV; Contact discharge: 6 kV. Lighting Protection: Common mode: 4 kV; Differential mode: 2 kV. Weight: 0.3 kg. Product Dimensions: 130 mm × 85 mm × 26 mm. Certifications CE; FCC. Transmission Performance: Switch power supply voltage 53V. CAT5E/CAT6. Max. DC resistance < 10ohm/100m Cable(m) Load Capacity(W) Bandwidth(Mbps) IEEE802.3bt 90W: 100m Cable; 71.3W Load Capacity; 100Mbps Bandwidth. 150m Cable; 62W Load Capacity; 10Mbps Bandwidth. 200m Cable; 51W Load Capacity; 10Mbps Bandwidth. 250m Cable; 40W Load Capacity; 10Mbps Bandwidth. Hi-PoE 60W: 100m Cable; 53W Load Capacity; 100Mbps Bandwidth. 150m Cable; 50W Load Capacity; 10Mbps Bandwidth. 200m Cable; 47W Load Capacity; 10Mbps Bandwidth. 250m Cable; 37W Load Capacity; 10Mbps Bandwidth. IEEE802.3at 30W: 100m Cable; 25.5W Load Capacity; 100Mbps Bandwidth. 150m Cable; 25.5WLoad Capacity; 10Mbps Bandwidth. 200m Cable; 25.5WLoad Capacity; 10Mbps Bandwidth. 250m Cable; 25.5WLoad Capacity; 10Mbps Bandwidth. Note: The actual transmission distance may vary due to power consumption of connected devices or the cable type and status.
Pirkti
Turime sandėlyje

SMA-male užspaudžiama jungtis RG6 kabeliui

€ 2.97  
SMA-male užspaudžiama jungtis RG6 kabeliui Techninis aprašymas: Jungties tipas: SMA-male. Kabelio tipas: RG6.
Pirkti
Turime sandėlyje

N-male užspaudžiama jungtis LMR-400 kabeliui

€ 2.97  
N-male užspaudžiama jungtis LMR-400 kabeliui Techninis aprašymas: Jungties tipas: N-male. Kabelio tipas: LMR-400. Varža: 50 omų.
Pirkti
Turime sandėlyje

SMA-female užspaudžiama jungtis RG6 kabeliui

€ 1.90  
SMA-female užspaudžiama jungtis RG6 kabeliui Techninis aprašymas: Jungties tipas: SMA-female. Kabelio tipas: RG6.
Pirkti
Turime sandėlyje

PoE šakotuvas valdomas 100Mbps 24portų+2G uplink + 2SFP, Hi-PoE

€ 510.10  
26 portų valdomas šakotuvas su 24 portų PoE, 250m, max 360W, modelis S4101-24ET2GF-360-C. Overview: Cloud Managed Switch is a layer-2 commercial switch that has a long-distance PoE function. It can supply power to devices up to 250 meters away. The PoE red port supplies up to 90W. The Switch can be managed through the DoLynk Care app, allowing you access to the network topology diagram function, which can be used to quickly identify issues. The DoLynk Care app is developed based on DoLynk Care Cloud Server. The Switch is applicable for use in a wide variety of scenarios, such as in homes, factories and offices. Model: S4101-24ET2GF-360-C. Functions: Supports LLDP protocol and automatically generating the network topology to quickly identify issues. Cloud Management: You can operate and maintain the switch on the app of the mobile terminal, greatly reducing the cost of operation and maintenance. The transmission distance of a PoE port can be up to 250 m, meeting the requirement of wired transmission (bandwidth reduced to 10Mbps). · Supports visualized management and remote maintenance. · Supports automatic network topology generation. · 250 m long-distance power supply. · 8-pin PoE offers better compatibility and reduces cable loss. · PoE watchdog monitors the status of terminals in real-time. · Supports the power management policy. Red Port 90W: The red ports support IEEE802.3af, IEEE802.3at, IEEE802.3bt and Hi-PoE standards, with a maximum output power consumption of 90W per port. Suitable for powering high-power devices. PoE Watchdog: It enables the switch to automatically detect port status and restart the failed ports to recover connection in case of IPC connection exception. This enables intelligent operation and maintenance management in its true sense and effectively reduces manual maintenance costs. Technical Specification: Included Power Adapter: Yes. PoE: Yes. Ethernet Port: 24. Ethernet Port Speed 10/100 Mbps. Optical Port Uplink Speed: 1 Gbps. Description of Function Slots: Port 1-24: 24 × 10M/100M Base-T (PoE); Port 25-26: 2 × 10M/100M/1000M Base-T (uplink)(combo); Port 25-26: 2 × 1000M SFP (uplink)(combo). Power Supply: 100–240 VAC, 50/60 Hz, 2 A. Operating Temperature: –10°C to +55°C. Operating Humidity: 5%–95% (RH), non-condensing. Storage Temperature –40°C to +70°C. Storage Humidity 5%–95% (RH), non-condensing. Power Consumption Idling: <5 W, Full: 360 W. MTBF: 337,713 h. Switching Capacity: 8.8 Gbps. Packet Forwarding Rate: 6.54 Mpps. Packet Buffer Size: 4 Mbit. MAC Table Size: 16K. PoE Protocol: IEEE802.3af; IEEE802.3at; Hi-PoE; IEEE802.3bt. PoE Power: Port 1–2 <90 W; Port 3–24 <30 W; Total <360 W. PoE Power Consumption Management: Yes. PoE Pin Assignment: 1, 2, 4, 5 (V+), 3, 6, 7, 8(V–). Long Distance PoE Transmission: Yes. Statics Protection: Air discharge: 8 kV; Contact discharge: 6 kV. Lighting Protection: Common mode: 4 kV; Differential mode: 2 kV. Weight: 3.50 kg. Product Dimensions: 440 mm × 300 mm × 44 mm. Certifications CE; FCC. Transmission Performance: Switch power supply voltage 53V. CAT5E/CAT6. Max. DC resistance < 10ohm/100m Cable(m) Load Capacity(W) Bandwidth(Mbps) IEEE802.3bt 90W: 100m Cable; 71.3W Load Capacity; 100Mbps Bandwidth. 150m Cable; 62W Load Capacity; 10Mbps Bandwidth. 200m Cable; 51W Load Capacity; 10Mbps Bandwidth. 250m Cable; 40W Load Capacity; 10Mbps Bandwidth. Hi-PoE 60W: 100m Cable; 53W Load Capacity; 100Mbps Bandwidth. 150m Cable; 50W Load Capacity; 10Mbps Bandwidth. 200m Cable; 47W Load Capacity; 10Mbps Bandwidth. 250m Cable; 37W Load Capacity; 10Mbps Bandwidth. IEEE802.3at 30W: 100m Cable; 25.5W Load Capacity; 100Mbps Bandwidth. 150m Cable; 25.5WLoad Capacity; 10Mbps Bandwidth. 200m Cable; 25.5WLoad Capacity; 10Mbps Bandwidth. 250m Cable; 25.5WLoad Capacity; 10Mbps Bandwidth. Note: The actual transmission distance may vary due to power consumption of connected devices or the cable type and status.
Pirkti
Turime sandėlyje

N-female užspaudžiama jungtis LMR-400 kabeliui

€ 2.97  
N-female užspaudžiama jungtis LMR-400 kabeliui Techninis aprašymas: Jungties tipas: N-female. Kabelio tipas: LMR-400. Varža: 50 omų.
Pirkti
Turime sandėlyje

PoE šakotuvas valdomas100Mbps 4portų+2G uplink

€ 53.38  
6 portų valdomas šakotuvas su 4 portų PoE, 250m, 30-40W. 6-Port Cloud Managed Desktop Switch with 4-Port PoE Model: CS4006-4ET2GT-36. Overview: • 4 × RJ45 10/100 Mbps PoE ports, 2 × RJ45 Gigabit ports. • 36 W total PoE budget, 802.3af/at on all PoE ports. • DIP switch to fast turn on/off working mode of Cloud-Managed, PoE Watchdog, Long Distance PoE. • Wide operating temperature ranging from –10 °C to 55 °C. • Supports VLAN and loop protection. • WEB-managed and centralized cloud management through the DoLynk App and performs real-time monitoring of the network. • Easy config to auto detect and set up network and systems. Functions: • Meets the requirements of IEEE802.3, IEEE802.3u, IEEE802.3x, IEEE802.3ab standards. • Meets the requirements of IEEE802.3af, IEEE802.3at power supply standards. • Manages PoE power consumption and PoE power on/off. Supports Intelligent PoE. • A wide operating temperature range and a full metal casing that is fully-enclosed and dust-proof. Technical Specification: Included Power Adapter: Yes. Switching Capacity: 4.8 Gbps. Packet Forwarding Rate: 3.57 Mpps. Description of Function Slots: Port 1-4: 4x RJ–45 10/100 Mbps; Port 5-6: 2x RJ-45 10/100/1000 Mbps (uplink). PoE: Yes. Power Supply: External power supply: 53 VDC, 0.8 A. Operating Temperature: –10°C to +55°C. Operating Humidity: 5%–95% (RH), non-condensing. Storage Temperature –40°C to +70°C. Storage Humidity 5%–95% (RH), non-condensing. Power Consumption Idling: <3 W; Full load: 42.4 W. MTBF: 232.62 years. Packet Buffer Size: 4 Mbit. MAC Table Size: 2K. PoE Protocol: IEEE802.3af; IEEE802.3at. Communication Standard: IEEE 802.3; IEEE 802.3u; IEEE 802.3X; IEEE 802.3ab. PoE Power: Port 1-4 < 30 W; Total < 40 W. PoE Power Consumption Management: Yes. PoE Pin Assignment: 1, 2, 4, 5 (V+), 3, 6, 7, 8(V–). Long Distance PoE Transmission: Yes. Statics Protection: Air discharge: 8 kV; Contact discharge: 6 kV. Lighting Protection: Common mode: 6 kV; Differential mode: 0 kV. Weight: 0.19 kg. Product Dimensions: 115 mm × 84 mm × 27 mm (4.53" × 3.33" × 1.06") DIP switch: Yes. Reset button: 1. VLAN Function: Port-based VLAN. VLAN Number: 32. DHCP Function: DHCP Client. Equipment Management: Web management; App management; Cloud Management.
Pirkti
Turime sandėlyje

PoE šakotuvas valdomas100Mbps 4portų+2G uplink

€ 62.87  
6 portų valdomas šakotuvas su 4 portų PoE, 250m, 30-60W. Model: CS4006-4ET2GT-60 6-Port Cloud Managed Desktop Switch with 4-Port PoE Overview: • 4 × RJ45 10/100 Mbps PoE ports, 2 × RJ45 Gigabit ports. • 60 W total PoE budget, 802.3af/at on all PoE ports, additional Hi-PoE on orange port. • DIP switch to fast turn on/off working mode of Cloud-Managed, PoE Watchdog, Long Distance PoE. • Wide operating temperature ranging from –10 °C to 55 °C. • Supports VLAN and loop protection. • WEB-managed and centralized cloud management through the DoLynk App and performs real-time monitoring of the network. • Easy config to auto detect and set up network and security systems Functions: • Meets the requirements of IEEE802.3, IEEE802.3u, IEEE802.3x, IEEE802.3ab, IEEE 802.3az standards. • Meets the requirements of IEEE802.3af, IEEE802.3at, Hi-PoE power supply standards. • Manages PoE power consumption and PoE power on/off. Supports Intelligent PoE. • A wide operating temperature range and a full metal casing that is fully-enclosed and dust-proof. Technical Specification: Included Power Adapter: Yes. Switching Capacity: 4.8 Gbps. Packet Forwarding Rate: 3.57 Mpps. Description of Function Slots: Port 1-4: 4x RJ-45 10/100 Mbps (PoE); Port 5-6: 2x RJ-45 10/100/1000 Mbps (uplink). PoE: Yes. Power Supply: External power supply: 53 VDC, 1.22 A. Operating Temperature: –10°C to +55°C. Operating Humidity: 10%–90% (RH), non-condensing. Storage Temperature –40°C to +70°C. Storage Humidity 5%–95% (RH), non-condensing. Power Consumption Idling: <3 W; Full load: 65 W. MTBF: 232.62 years. Packet Buffer Size: 4 Mbit. MAC Table Size: 2K. PoE Protocol: IEEE802.3af; IEEE802.3at; Hi-PoE. Communication Standard: IEEE 802.3; IEEE 802.3u; IEEE 802.3X; IEEE 802.3ab; IEEE 802.3az. PoE Power: Port 1-4 < 30 W; Total < 60 W. PoE Power Consumption Management: Yes; PoE power on/off; turns off PoE if overload is detected. PoE Pin Assignment: 1, 2, 4, 5 (V+), 3, 6, 7, 8(V-). Long Distance PoE Transmission: Yes. Statics Protection: Air discharge: 8 kV; Contact discharge: 6 kV. Lighting Protection: Common mode: 6 kV. Weight: 0.2 kg. Product Dimensions: 115 mm × 84 mm × 27 mm (4.53" × 3.33" × 1.06") DIP switch: Yes. Reset button: 1. VLAN Function: IEEE 802.1Q VLAN. VLAN Number: 32. DHCP Function: DHCP Client. Equipment Management: Web management; Cloud Management; Logs; Fault Alarm.
Pirkti
Turime sandėlyje

SMA-male užspaudžiama jungtis LMR-400 kabeliui

€ 1.90  
SMA-male užspaudžiama jungtis LMR-400 kabeliui Techninis aprašymas: Jungties tipas: SMA-male. Kabelio tipas: LMR-400. Varža: 50 omų.
Pirkti
Susisiekti dėl likučio